APC Symmetra LX 16kVA Scalable to 16kVA N+1 Ext. Run Tower, 220/230/240V or 380/400/415V, Input Voltage: 230, 400 3PH, Output Voltage: 230, Shipping Weight: 1178.00(lbs) 535.45(kilos), Shipping Dimensions: 74.00x 23.60x 39.25(in) 188.00x 59.90x 99.70(cent)

© Respective owners and brand holders. © 2026 Laptop Direct CC. The contents has been generated by Laptop Direct CC (https://www.laptopdirect.co.za). All products are sourced locally in South Africa and the warranty is that of the local supplier only. E&OE.

Long Description

The specifications displayed below are for the entire series of products and may not apply to this product or model, please refer to the above description for the correct details of this model.

Features:

Removable input/output wiring tray
Allows quick and easy installation and maintenance of the UPS.

Availability

Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Configurable for N+1 internal redundancy
Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Battery modules connected in parallel
Delivers higher availability through redundant batteries.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.

Scalability

Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.

Scalable runtime
Allows additional run time to be quickly added as needed.

Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.

Programmable frequency
Ensures compatibility with different input frequencies.

Manageability

Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.

Network manageable
Provides remote power management of the UPS over the network.

InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.

LCD display
Alpha-Numeric Display which displays system parameters and alarms.

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

SmartSlot
Customize UPS capabilities with management cards.

Serviceability

Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.

User-replaceable intelligence modules
Enables simple upgrades and replacements of the Intelligence Modules.

User-replaceable power modules
Enables simple upgrades and replacements of the Power Modules.

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Protection

Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.

Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.

Generator compatible
Ensures clean, uninterrupted power to the loads in the event of an extended power outage

Cold-start capable
Provides temporary battery power when the utility power is out.

Resettable circuit breakers
Enables a quick recovery from overload events.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.


Specifications:

© 2014 Respective owners and brand holders. This table has been carefully researched and generated by Laptop Direct CC (https://www.laptopdirect.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered.
Specificationsspacer
Product CodeSYA16K16IXRspacer
Output
Output Power Capacity 11.2 kW / 16 kVA
Max Configurable Power 11.2 kW / 16 kVA
Nominal Output Voltage 230V
Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage
Efficiency at Full Load 0.9
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains) 47 - 63 Hz
Other Output Voltages 220, 240
Crest Factor up to 5 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections (1) Hard Wire 3-wire (H N + G)
Bypass Internal Bypass (Automatic and Manual)
Input
Nominal Input Voltage 230V, 400V 3PH
Input Frequency 45 - 65 Hz (auto sensing)
Input Connections Hard Wire 3 wire (1PH+N+G)
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 155 - 276 (1:1), 290 - 480 (3:1)V
Other Input Voltages 220V, 240V, 380V, 415V
Input Total Harmonic Distortion Less than 7% for full load
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Included Battery Modules 9
Available Battery Module Slots 4
Typical recharge time 7.50 hour(s)
Replacement Battery SYBT5
Communications & Management
Interface Port(s) DB-9 RS-232, RJ-45 10/100 Base-T, Smart-Slot
Available SmartSlot Interface Quantity 1
Pre-Installed SmartSlot Cards AP9631
Control panel Multi-function LCD status and control console
Audible Alarm Audible and visible alarms prioritized by severity
Emergency Power Off (EPO) Yes
Physical
Maximum Height 1516.00 mm
Maximum Width 483.00 mm
Maximum Depth 726.00 mm
Net Weight 503.64 KG
Shipping Weight 535.45 KG
Shipping Height 1880.00 mm
Shipping Width 599.00 mm
Shipping Depth 997.00 mm
Color Black, Silver
Environmental
Operating Environment 0 - 40 °C
Operating Relative Humidity 0 - 95%
Operating Elevation 0-3000 meters
Storage Temperature -15 - 45 °C
Storage Relative Humidity 0 - 95%
Storage Elevation 0-4500 meters
Audible noise at 1 meter from surface of unit 62.00 dBA
Online Thermal Dissipation 3707.00 BTU/hr
Conformance
Regulatory Approvals C-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 55024, EN 60950, GOST, IEC 60950, VDE



©2026 Laptop Direct CC

E&OE Errors may occur and information is for reference purposes only and are subject to change without notice.
Images are for reference only. You may not copy, duplicate, reproduce the contents of this page or any other page for use in any e-commerce site or pricelists.

You may share this page, print and use sections of the text for reference purposes on condition that there is a clear and explicit credit to this site, ie: "https://www.LaptopDirect.co.za" must appear as a referal at all times.

Order now
Available at LaptopDirect.co.za
  Webafrica Fibre